I just replaced my Exabyte VXA-2 tape drive with VXA-320 autochanger. I can't remember there had ever been any problem with labeling the tapes before. Blank brand new tapes could be labeled staright from the package, I think. But I haven't labeled tapes with the old drive for a few months.
Now, label barcodes console command results in the following error message: 3912 Failed to label Volume: ERR=dev.c:678 Rewind error on "VXA320" (/dev/nst0). ERR=Input/output error. If I set autochanger=no, there also is an error message, but labeling seems to work anyway. And if I run mt -f /dev/nst0 rewind mt -f /dev/nst0 weof labeling (with autochanger=yes) works ok withut any errors. In the following, I had written EOF to the tape in slot 1, in slot 2 there is a brand new tape. Is this spesific to my hardware, or has someone else met the same problem? Or is it a requirement that tapes need to be "prepared" with mt? Bacula 1.38.10-3 on FC4 *label barcodes Using default Catalog name=MyCatalog DB=bacula The defined Storage resources are: 1: File 2: Exabyte Autoloader Select Storage resource (1-2): 2 Connecting to Storage daemon Exabyte Autoloader at dogbert:9103 ... 3306 Issuing autochanger "slots" command. Device "Exabyte Autoloader" has 10 slots. Connecting to Storage daemon Exabyte Autoloader at dogbert:9103 ... 3301 Issuing autochanger "loaded drive 0" command. 3302 Autochanger "loaded drive 0", result is Slot 1. 3307 Issuing autochanger "unload slot 1, drive 0" command. 3306 Issuing autochanger "list" command. The following Volumes will be labeled: Slot Volume ============== 1 A0000001 2 A0000002 Do you want to continue? (yes|no): y Automatically selected Pool: Default Connecting to Storage daemon Exabyte Autoloader at dogbert:9103 ... Sending label command for Volume "A0000001" Slot 1 ... 3301 Issuing autochanger "loaded drive 0" command. 3302 Autochanger "loaded drive 0", result: nothing loaded. 3304 Issuing autochanger "load slot 1, drive 0" command. 3305 Autochanger "load slot 1, drive 0", status is OK. 3301 Issuing autochanger "loaded drive 0" command. 3302 Autochanger "loaded drive 0", result is Slot 1. 3000 OK label. Volume=A0000001 Device="VXA320" (/dev/nst0) Catalog record for Volume "A0000001", Slot 1 successfully created. Sending label command for Volume "A0000002" Slot 2 ... 3301 Issuing autochanger "loaded drive 0" command. 3302 Autochanger "loaded drive 0", result is Slot 1. 3307 Issuing autochanger "unload slot 1, drive 0" command. 3304 Issuing autochanger "load slot 2, drive 0" command. 3305 Autochanger "load slot 2, drive 0", status is OK. 3301 Issuing autochanger "loaded drive 0" command. 3302 Autochanger "loaded drive 0", result is Slot 2. 3301 Issuing autochanger "loaded drive 0" command. 3302 Autochanger "loaded drive 0", result is Slot 2. 3912 Failed to label Volume: ERR=dev.c:678 Rewind error on "VXA320" (/dev/nst0). ERR=Input/output error. Regards, Timo Using Tomcat but need to do more? Need to support web services, security? Get stuff done quickly with pre-integrated technology to make your job easier Download IBM WebSphere Application Server v.1.0.1 based on Apache Geronimo http://sel.as-us.falkag.net/sel?cmd=lnk&kid=120709&bid=263057&dat=121642 _______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users