---------- Forwarded message ----------
From: John Drescher <[EMAIL PROTECTED]>
Date: Sep 26, 2006 3:57 PM
Subject: Re: [Bacula-users] ERR=Cannot allocate memory when mounting a tape from an autochanger.
To: Arno Lehmann <[EMAIL PROTECTED]>

> Any Ideas?

Yup, that looks as though the tape is blank.

Have you tried btape and the command readlabel on that tape? Also, 'dd |
od' or whatever flavour of that command you prefer can tell you if the
tape holds a Bacula label. Then, finally, do you have system log
messages regarding your tape drive?


Thanks for the info.

Initially I used label barcodes command to label all 23 tapes in the autochanger a few weeks back and I have not written to this tape since.

I had already soved this problem by using the delete volume command then unmount. Then the mtx command to physically mount the media in the first drive and finally a mount and bacula labeled  the tape. I guess I should have waited at least few minutes before implementing workarounds as I would have probably been able to figure out the cause of the problem.

Thanks,
John


--
John M. Drescher
-------------------------------------------------------------------------
Take Surveys. Earn Cash. Influence the Future of IT
Join SourceForge.net's Techsay panel and you'll get the chance to share your
opinions on IT & business topics through brief surveys -- and earn cash
http://www.techsay.com/default.php?page=join.php&p=sourceforge&CID=DEVDEV