Hi, 24.07.2007 18:24,, Berthaud wrote:: > Hi > > My server bacula (version 1.38.11) works with a tape library Overland. I use > two tapes each week. > > Sometimes Bacula load the second tape when the first is full. Sometimes not. > > Before full save of the 10 servers I delete the two tapes with gconsole , > stop > bacula, erase the two tape, restart bacula and relabel it with gconsole. > > Sometimes it fill completly the first one and don't go to get the other tape > in > the other slot. Sometimes bacula change the tape automatiquely and start > filling the second one. > > Example of gconsole messages when it is not working > > 24-jui 03:21 intbd2-dir: Start Backup JobId 381, Job=Sauveintbd1.2007-07- > 23_18.51.04 > 24-jui 05:32 intbd2-sd: End of Volume "NLU063L2" at 492:10660 on device "LTO- > 2N1" (/dev/nst0). Write of 64512 bytes got -1. > 24-jui 05:32 intbd2-sd: Re-read of last block succeeded. > 24-jui 05:32 intbd2-sd: End of medium on Volume "NLU063L2" > Bytes=483,234,214,885 Blocks=7,490,616 at 24-jui-2007 05:32. > 24-jui 05:33 intbd2-sd: 3301 Issuing autochanger "loaded drive 0" command. > 24-jui 05:33 intbd2-sd: 3302 Autochanger "loaded drive 0", result is Slot 1. > 24-jui 05:33 intbd2-sd: Sauveintbd1.2007-07-23_18.51.04 Warning: Director > wanted Volume "NLU062L2" for device "LTO-2N1" (/dev/nst0). > Current Volume "NLU063L2" not acceptable because: > 1998 Volume "NLU063L2" status is Full, but should be Append, Purged or > Recycle. > 24-jui 05:33 intbd2-sd: 3301 Issuing autochanger "loaded drive 0" command. > 24-jui 05:33 intbd2-sd: 3302 Autochanger "loaded drive 0", result is Slot 1. > 24-jui 05:33 intbd2-sd: Sauveintbd1.2007-07-23_18.51.04 Warning: Director > wanted Volume "NLU062L2" for device "LTO-2N1" (/dev/nst0). > > Device status: > Autochanger "overland" with devices: > "LTO-2N1" (/dev/nst0) > Device "LTO-2N1" (/dev/nst0) is mounted with Volume="NLU063L2" Pool="Default" > Device is BLOCKED waiting for media. > Slot 1 is loaded in drive 0. > Total Bytes Read=64,512 Blocks Read=1 Bytes/block=64,512 > Positioned at File=0 Block=0 > ==== > > In Use Volume status: > NLU063L2 on device "LTO-2N1" (/dev/nst0) > ==== > > > > Mount and unmount does not do nothing > > The only way I found to unlock this situation is to delete the volume > NLU062L2 > in bacula mysql database, unmount the drive with gconsole, erase the tape, > mount the drive with gconsole and label it again with gconsole > > Why should I do in order to have bacula loading systematicaly the second tape?
Your problem description looks like the autochanger setup might be faulty. Have you tried the btape tests for the autochanger, and can you use mtx-changer from the console? Also, make sure the catalog reflects the actual autochanger inventory. Check using the query to list the volumes in the autochanger, and, if that's not correct, use 'update slots [scan] storage=overland'. Arno > Regards > > > Christian > > > > ------------------------------------------------------------------------- > This SF.net email is sponsored by: Splunk Inc. > Still grepping through log files to find problems? Stop. > Now Search log events and configuration files using AJAX and a browser. > Download your FREE copy of Splunk now >> http://get.splunk.com/ > _______________________________________________ > Bacula-users mailing list > [email protected] > https://lists.sourceforge.net/lists/listinfo/bacula-users -- Arno Lehmann IT-Service Lehmann www.its-lehmann.de ------------------------------------------------------------------------- This SF.net email is sponsored by: Splunk Inc. Still grepping through log files to find problems? Stop. Now Search log events and configuration files using AJAX and a browser. Download your FREE copy of Splunk now >> http://get.splunk.com/ _______________________________________________ Bacula-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/bacula-users