Hi Arno,

Added "Two EOF = Yes" and re-ran the btape test and the problem disappeared.

Thanks again!!

Win



>
>
>
>
> Hi,
>
> 08.11.2007 15:17,, Win Htin wrote::
> > Hi folks,
> >
> > Just as I thought I have fixed my problems, I am again stumped with
> > Volumes being put into Error with  "/*Error: Unable to position to end
> > of data on device*/" messages.
> >
> > As previously mentioned in my other post, all the tapes were erased once
> > over to make sure everything starts cleanly. The tapes were bought brand
> > new from IBM and some were used previously for my Bacula tests (btape +
> > actual backups).
> >
> > analysing the pattern, I suspect once all the backups are done EOF/EOD
> > is not written to the tape/volume causing next run(s) to put the tape
> > into Error and use the next available volume.
>
> Have you set "Two EOF = Yes" in the SD configuration? Seems like
> setting that, and "BSF at EOM", too, might help you... you'll have to try.
>
> Arno
>
-------------------------------------------------------------------------