Bob Hetzel schrieb: > > I'm running v 2.4.3 of bacula on OpenSuse 10.2 with a two tape-drive > autoloader and I've been having this problem every few days for a > while > now: bacula wants a tape that's already loaded but in a different > drive > and it's not able to just unload the tape and move it or better yet > just > use it where it's already mounted on the other drive. > > 23-Dec 03:02 gyrus-sd JobId 50576: Please mount Volume "LTO289L2" or > label a new one for: > Job: arc2-gx280.2008-12-22_19.30.24 > Storage: "IBMLTO2-1" (/dev/nst0) > Pool: Default > Media type: LTO-2 >
Same problem here. Sadly this seems to be one of bacula's limitations in volume/device handling. http://bugs.bacula.org/view.php?id=1207 | 0003854) | kern (administrator) | 2008-12-20 18:23 | | All Volume read operations in Bacula are one job at a time. | You must ensure that two jobs do not attempt to read the same | Volume at the same time via scheduling or priorities. If two | jobs do, the first one will get the Volume and the second job | will most likely find itself in a bad position not knowing if | the volume will ever be available so it asks for operator | intervention. | This is not a bug. ~ I'm not sure if this is limited to jobs that wants to read from a tape. Ralf ------------------------------------------------------------------------------ _______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users