I'm setting up bacula on a new machine with a new Dell LT04 autoloader. The device appears to be registering with linux (rhel 5.5). All fd,sd and dir daemons are running.
[r...@scrappy bacula]# dmesg | grep "tape" st 2:0:0:0: Attached scsi tape st0 However I get a "no slots in changer" error when run 'status slots'. *status slots ... Connecting to Storage daemon Tape at scrappy.microslu.washington.edu:9103 ... 3306 Issuing autochanger "slots" command. Device "DELL_124T" has 0 slots. No slots in changer to scan. I also tried running 'mtx' manually. Any thoughts? [r...@scrappy bacula]# mtx -f /dev/sg0 status mtx: Request Sense: Long Report=yes mtx: Request Sense: Valid Residual=no mtx: Request Sense: Error Code=70 (Current) mtx: Request Sense: Sense Key=Illegal Request mtx: Request Sense: FileMark=no mtx: Request Sense: EOM=no mtx: Request Sense: ILI=no mtx: Request Sense: Additional Sense Code = 20 mtx: Request Sense: Additional Sense Qualifier = 00 mtx: Request Sense: BPV=no mtx: Request Sense: Error in CDB=no mtx: Request Sense: SKSV=no READ ELEMENT STATUS Command Failed Jeremiah Jester Senior Informatics Specialist UW Microbiology - Katze Lab P: 206-732-6185
------------------------------------------------------------------------------ This SF.net email is sponsored by Make an app they can't live without Enter the BlackBerry Developer Challenge http://p.sf.net/sfu/RIM-dev2dev
_______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users