Hello Josh.

Have you tried restricting the number of concurrent jobs in the device
> definition in bacula-sd, as opposed to elsewhere? for example:
>

Yes, it already is set to only 1 concurrent Job in bacula-sd.conf, but the
problem is that, in my SD server, I have multiple IP address on multiple
different VLANs. And in Bacula, one Storage definition can only have one IP
address, so I had to create different Storage definition, one for each
VLAN, but all pointing to the same Device in bacula-sd.conf. Although
Bacula thinks I have several SD, each one with 1 concurrent Job max, in the
end, there is only one Device in bacula-sd limiting to run only one Job at
a time.

That works great, but my problem is another: when a Job gets upgraded from
Inc to Full (because is a new client config in bacula-dir.conf), the
Director use the wrong Storage to write to the Full pool.

In short: I have the options "Full Pool" and "Incremental Pool" in the Job,
but I don't have a "Full Storage" and "Incremental Storage" to tell Bacula
to also change the Storage when the Job is upgraded from Inc to Full...

I guess is really hard to understand my problem, but I'll post a summary of
my Bacula configs to try to clarify. But thank you very much for your help.
------------------------------------------------------------------------------
Live Security Virtual Conference
Exclusive live event will cover all the ways today's security and 
threat landscape has changed and how IT managers can respond. Discussions 
will include endpoint security, mobile security and the latest in malware 
threats. http://www.accelacomm.com/jaw/sfrnl04242012/114/50122263/
_______________________________________________
Bacula-users mailing list
Bacula-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-users

Reply via email to