On Wed, Jan 9, 2013 at 4:13 PM, Jonathan Horne <jho...@skopos.us> wrote: > i have a 44 slot PV-TL4000 that i have just brought online with my bacula. > my first attempt at labeling the media based on the barcodes failed. below > is the output, can anyone give me some ideas on what to start checking? > > > *label barcodes > Automatically selected Catalog: MyCatalog > Using Catalog "MyCatalog" > The defined Storage resources are: > 1: File > 2: PV-TL4000 > Select Storage resource (1-2): 2 > Connecting to Storage daemon PV-TL4000 at d0lppb021.skopos.me:9103 ... > Enter autochanger drive[0]: > Connecting to Storage daemon PV-TL4000 at d0lppb021.skopos.me:9103 ... > 3306 Issuing autochanger "slots" command. > Device "PV-TL4000" has 47 slots. > Connecting to Storage daemon PV-TL4000 at d0lppb021.skopos.me:9103 ... > 3306 Issuing autochanger "list" command. > The following Volumes will be labeled: > Slot Volume > ============== > 1 SK1004L3 > 2 SK1006L3 > 3 SK1009L3 > Do you want to label these Volumes? (yes|no): yes > Defined Pools: > 1: MonthlyBackups > 2: FullBackups > 3: IncrementalBackups > 4: DifferentialBackups > 5: TapeArchiveFullBackups > 6: Default > 7: Scratch > 8: YearlyBackups > Select the Pool (1-8): 5 > Connecting to Storage daemon PV-TL4000 at d0lppb021.skopos.me:9103 ... > Sending label command for Volume "SK1004L3" Slot 1 ... > 3301 Issuing autochanger "loaded? drive 0" command. > 3302 Autochanger "loaded? drive 0", result: nothing loaded. > 3304 Issuing autochanger "load slot 1, drive 0" command. > 3992 Bad autochanger "load slot 1, drive 0": ERR=Child died from signal 15: > Termination. > Results=Program killed by Bacula (timeout) > > Label command failed for Volume SK1004L3. > Sending label command for Volume "SK1006L3" Slot 2 ... > 3301 Issuing autochanger "loaded? drive 0" command. > 3302 Autochanger "loaded? drive 0", result is Slot 1. > 3307 Issuing autochanger "unload slot 1, drive 0" command. > 3304 Issuing autochanger "load slot 2, drive 0" command. > 3992 Bad autochanger "load slot 2, drive 0": ERR=Child died from signal 15: > Termination. > Results=Program killed by Bacula (timeout) > > Label command failed for Volume SK1006L3. > Sending label command for Volume "SK1009L3" Slot 3 ... > 3301 Issuing autochanger "loaded? drive 0" command. > 3302 Autochanger "loaded? drive 0", result is Slot 2. > 3307 Issuing autochanger "unload slot 2, drive 0" command. > 3304 Issuing autochanger "load slot 3, drive 0" command. > 3992 Bad autochanger "load slot 3, drive 0": ERR=Child died from signal 15: > Termination. > Results=Program killed by Bacula (timeout) > > Label command failed for Volume SK1009L3. > * > > i did see that the tape was actually loaded in the drive, but i was afk > during all the failures. (ha, imagine my disappointment when i got back > that all 3 attempts failed! hehe)
You probably need to edit the mtx-changer script. It does not appear to detect when a slot is loaded for your system. John ------------------------------------------------------------------------------ Master Java SE, Java EE, Eclipse, Spring, Hibernate, JavaScript, jQuery and much more. Keep your Java skills current with LearnJavaNow - 200+ hours of step-by-step video tutorials by Java experts. SALE $49.99 this month only -- learn more at: http://p.sf.net/sfu/learnmore_122612 _______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users