Le 21/03/2013 14:34, Sven Tegethoff a écrit : > On 21.03.2013 13:57, giggzounet wrote: >> mailslot1 (Slot=46) : name of the new volume: FSI-PfS-1a_1__1 >> mailslot2 (Slot=47) : name of the new volume: FSI-PfS-1a_1__2 >> mailslot3 (Slot=48) : name of the new volume: FSI-PfS-1a_1__3 >> >> the problem is in bconsole a "list media" always gives the old "FSI-LES" >> in the slot 46. And of course it generates some errors, when I want to >> use it to bakcup. >> >> How can I solve this problem ? > > Did you do a "update slots" (or "update slots scan" if you're not using > barcodes) after exchanging the tapes? >
Hi, I did not do that, after removing the tape. But after exchanging the tapes and it doesn't work. I get an error on the slot 46: 3307 Issuing autochanger "unload slot 45, drive 0" command. 3304 Issuing autochanger "load slot 46, drive 0" command. 3305 Autochanger "load slot 46, drive 0", status is OK. 3001 Volume=FSI-PfS-1a_1__1 Slot=46 Volume "FSI-PfS-1a_1__1" not found in catalog. Slot=46 InChanger set to zero. Best regards ------------------------------------------------------------------------------ Everyone hates slow websites. So do we. Make your web apps faster with AppDynamics Download AppDynamics Lite for free today: http://p.sf.net/sfu/appdyn_d2d_mar _______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users