On 12/17/2021 9:56 am, Heitor Faria wrote:
Hello Larry,

Your jobs do not show the need for a new volume. However, your
configuration does not look good:

"Pool {
  Name = Default
  Pool Type = Backup
Recycle = yes # Bacula can automatically recycle Volumes
  AutoPrune = yes                     # Prune expired volumes
  *Volume Retention = 0*
  LabelFormat="LERCTR-"
  #Use Volume Once = yes
  #Maximum Volume Jobs = 4
  Maximum Volume Bytes=100GB
  Volume Use Duration = 12h
  Action On Purge = Truncate
  Recycle Oldest Volume = no
}"

Its unusual to have a VolumeRetention=0, in fact I believe Bacula
could even understand it as infinite. It should mess the Bacula
recycling algortithm.

Regards,

That was called out in the 11 release notes as letting the JOB retentions
determine volume retentions.

Did I misread something?  That was new with 11.
--
Larry Rosenman                     http://www.lerctr.org/~ler
Phone: +1 214-642-9640                 E-Mail: l...@lerctr.org
US Mail: 5708 Sabbia Dr, Round Rock, TX 78665-2106


_______________________________________________
Bacula-users mailing list
Bacula-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-users