On 12/17/2021 9:56 am, Heitor Faria wrote:
Hello Larry,
Your jobs do not show the need for a new volume. However, your
configuration does not look good:
"Pool {
Name = Default
Pool Type = Backup
Recycle = yes # Bacula can automatically
recycle Volumes
AutoPrune = yes # Prune expired volumes
*Volume Retention = 0*
LabelFormat="LERCTR-"
#Use Volume Once = yes
#Maximum Volume Jobs = 4
Maximum Volume Bytes=100GB
Volume Use Duration = 12h
Action On Purge = Truncate
Recycle Oldest Volume = no
}"
Its unusual to have a VolumeRetention=0, in fact I believe Bacula
could even understand it as infinite. It should mess the Bacula
recycling algortithm.
Regards,
That was called out in the 11 release notes as letting the JOB
retentions
determine volume retentions.
Did I misread something? That was new with 11.
--