Dear bacula-users, I am using bacula 9.4.2 on Ubuntu 20.04.4.
Recently I discovered 2 new configuration options: „Max Virtual Full Interval" and "Virtual Full Backup Pool“. As I already use MaxDiffInterval and MaxFullInterval I wanted to use them. But no matter what I configured I was not able to get a running configuration. Each virtual full ends up with a fatal error "Read and write devices not properly initialized.“ Explanations: Pools Full, Diff and Incr should be used as source and pool Full as destination pool. Devices GebM0 and GebM1 are part of Storage DiskM which is the Storage device for pool Full. I should say that, even if configuring another pool device as Virtual Full Backup Pool the fatal error still remains. I uploaded cleared up versions of bacula-dir.conf and bacula-sd.conf to https://cloud.uni-koblenz-landau.de/s/CYHZYzdATKcsLwf Any hint is greatly appreciated. Thanks a lot in advance. 10-Mai 00:07 bacula-dir JobId 1545775: 10-Mai 00:07 bacula-dir JobId 1545775: No prior or suitable Full backup found in catalog. Doing Virtual FULL backup. 10-Mai 00:07 bacula-dir JobId 1545775: Start Virtual Backup JobId 1545775, Job=unikodc02.2022-05-10_00.07.02_09 10-Mai 00:07 bacula-dir JobId 1545775: Consolidating JobIds=1497692,1537954,1538361,1538776,1538915,1539052,1539995,1540410,1540830,1541242,1541654,1541793,1541939,1542890,1543303,1543718,1544129,1544541 10-Mai 00:07 bacula-dir JobId 1545775: Found 705099 files to consolidate into Virtual Full. 10-Mai 00:07 bacula-dir JobId 1545775: Using Device "GebM1" to write. 10-Mai 00:07 bacula-sd JobId 1545775: Fatal error: Read and write devices not properly initialized. 10-Mai 00:07 bacula-sd JobId 1545775: Elapsed time=458926:07:50, Transfer rate=0 Bytes/second 10-Mai 00:07 bacula-dir JobId 1545775: Error: Bacula bacula-dir 9.4.2 (04Feb19): Build OS: x86_64-pc-linux-gnu ubuntu 20.04 JobId: 1545775 Job: unikodc02.2022-05-10_00.07.02_09 Backup Level: Virtual Full Client: "unikodc02" 5.2.10 (28Jun12) Microsoft Standard Edition (build 9200), 64-bit,Cross-compile,Win64 FileSet: "unikodc01-02 Files" 2015-02-18 00:09:03 Pool: "Full" (From Job VFullPool override) Catalog: "MyCatalog" (From Client resource) Storage: "DiskM" (From Pool resource) Scheduled time: 10-Mai-2022 00:07:02 Start time: 07-Mai-2022 00:07:18 End time: 07-Mai-2022 00:18:29 Elapsed time: 11 mins 11 secs Priority: 10 SD Files Written: 0 SD Bytes Written: 0 (0 B) Rate: 0.0 KB/s Volume name(s): Volume Session Id: 4175 Volume Session Time: 1651219107 Last Volume Bytes: 8,250,903,080 (8.250 GB) SD Errors: 1 SD termination status: Error Termination: *** Backup Error *** -- Kind regards Christoph _________________________________________ Christoph Litauer Uni Koblenz, Computing Centre, Office A 022 Postfach 201602, 56016 Koblenz Fon: +49 261 287-1311, Fax: -100 1311 _______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users