I would add that this problem appears to occur when all in-changer tapes are unavailable due to volume status AND the job's pool does contain available tapes, but those tapes are not in-changer. Bacula will attempt to load a tape that is not in-changer, where it should send an operator intervention notice.

On 5/12/23 06:22, Marco Gaiarin wrote:
We have some setups using bacula (debian buster, 9.4.2-2+deb10u1) and RDX
media, by the way of the 'vchanger' (Virtual Changer) script.

All works as expected, until the current mounted media exaust the 'in
changer' media (because exausted it; or because simply users load the
incorrect media...).

After that, bacula try to mount expired (purge them) or generically
avaliable volumes from other media, that are 'not in changer', putting them
on error.
We have extensivaly debugged vchanger script, that seems behave correctly.

Bacula seems have a current and correct state of 'in changer' volumes, and
anyway a 'update volumes' on console does not solve the trouble.


On director we have:

Autochanger {
        Name = SDPVE2RDX
        Address = sdpve2.sd.lnf.it
        SDPort = 9103
        Password = "unknown"
        Maximum Concurrent Jobs = 5
        Device = RDXAutochanger
        Media Type = RDX
}

Pool {
        Name = VEN-SD-SDPVE2RDXPool
        Pool Type = Backup
        Volume Use Duration = 1 days
        Maximum Volume Jobs = 1
        Recycle = yes
        AutoPrune = yes
        Action On Purge = Truncate
        Volume Retention = 20 days
}


On SD we have:

Autochanger {
   Name = RDXAutochanger
   Device = RDXStorage0
   Device = RDXStorage1
   Device = RDXStorage2
   Changer Command = "/usr/bin/vchanger %c %o %S %a %d"
   Changer Device = "/etc/vchanger/SDPVE2RDX.conf"
}

Device {
   Name = RDXStorage0
   Drive Index = 0
   Device Type = File
   Media Type = RDX
   RemovableMedia = no
   RandomAccess = yes
   Maximum Concurrent Jobs = 1
   Archive Device = "/var/spool/vchanger/SDPVE2RDX/0"
}

Device {
   Name = RDXStorage1
   Drive Index = 1
   Device Type = File
   Media Type = RDX
   RemovableMedia = no
   RandomAccess = yes
   Maximum Concurrent Jobs = 1
   Archive Device = "/var/spool/vchanger/SDPVE2RDX/1"
}

Device {
   Name = RDXStorage2
   Drive Index = 2
   Device Type = File
   Media Type = RDX
   RemovableMedia = no
   RandomAccess = yes
   Maximum Concurrent Jobs = 1
   Archive Device = "/var/spool/vchanger/SDPVE2RDX/2"
}


Someone have some clue? Thanks.