We're running Bacula v13.0.1. Some of our backups are to S3 which then go to Glacier after a set period of time. When doing restores from S3, the necessary file is downloaded automatically from S3 but, if it involves Glacier, it appears that no attempt is made to retrieve the file. Bacula just sits waiting for the part file, so we have to actually manually initiate the retrieval from Glacier and then Bacula continues once the part file has appeared in S3. https://www.bacula.org/13.0.x-manuals/en/main/Storage_Daemon_Configuratio.html seems to indicate that Bacula works with AWS Glacier as it states:
Transfer Priority = <High | Medium | Low> > When restoring directly a part from Glacier, this directive indicates the > rehydration priority level. Values can be High, Medium or Low. Default is > High. Those values match respectively Expeditive, Standard and Bulk transfers > tiers within S3. We configured Transfer Priority = "Low" so we expected it to use the Bulk transfer tier - see https://docs.aws.amazon.com/amazonglacier/latest/dev/downloading-an-archive-two-steps.html. Is Bacula capable of initiating the Glacier restore? Or is that config (Transfer Priority) not what we thought? Thanks. -- Samantha Falconer Senior Systems Administrator <http://www.maglabs.net> T: 0203 515 1000 | www.maglabs.net | Follow us <https://bit.ly/3x215vn> MagLabs Limited is a Limited Liability Company registered at Companies House, Cardiff. Registration No 06715580. DISCLAIMER: This email and any attachments sent with it may contain confidential and legally privileged information. It is intended solely for the individual or entity to whom the email was addressed. If you are not the intended recipient please notify the sender via email immediately, delete the email (and attachments) from your computer system and destroy any copies you may have in your possession. You are prohibited from using, printing, copying or disclosing any of the information contained within the email and its attachment(s). MagLabs Limited does not accept any responsibility or liability for any changes made to this email after it was sent or for any viruses transmitted through it. Opinions, comments, and conclusions made in this email may be that of the author and may not reflect the view of MagLabs Limited. Please consider the environment before printing this email
_______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users