What do you think about MSL 2040 instead of MSL 1/8 ? Are there the same
autochager
capabilities ?
>From Bacula point of view is the same device ?
Bye
Enrico

Il giorno dom 3 mar 2024 alle ore 08:12 enrico.becche...@gmail.com <
enrico.becche...@gmail.com> ha scritto:

> many thanks for these informations.
> Best regards
> Enrico
>
> Il giorno dom 3 mar 2024 alle ore 03:23 Gary R. Schmidt <
> g...@mcleod-schmidt.id.au> ha scritto:
>
>> On 03/03/2024 03:50, enrico.becche...@gmail.com wrote:
>> >
>> > Dear all, I need to build a backup system and I would like to use
>> > Bacula. My project involves an HP Store Ever MSL 1/8 library with an
>> > LTO-8 fiber channel drive. The Bacula server will be an HP Proliant
>> > DL380 Gen8 running Almalinux 8 or 9. My idea is to have automatic tape
>> > management with Bacula sending the tape change command when needed, and
>> > the library identifying the correct cartridge using the barcode. Do you
>> > think Bacula can handle all of this with the hardware I have specified?
>>
>> Yes.  I have a previous version of that autoloader running an LTO06 tape
>> drive.
>>
>> I had to set the timeouts to 30 seconds in mtx-changer.conf, and changed
>> the mtx-changer script thus:
>>
>> =======================
>> wait_for_drive() {
>>    i=0
>>    while [ $i -le 300 ]; do  # Wait max 300 seconds
>>      # grs, try once before checking...
>>      mt -f $1 status > /dev/null 2>&1
>>      if mt -f $1 status 2>&1 | grep "${ready}" >/dev/null 2>&1; then
>>        break
>>      fi
>>      debug $dbglvl "Device $1 - not ready, retrying..."
>>      sleep 1
>>      i=`expr $i + 1`
>>    done
>> }
>> =======================
>>
>> And, in the "list)" command, I changed
>> =======================
>> ##      cat ${TMPFILE} | grep " Storage Element [0-9]*:.*Full" | awk
>> "{print \$3 \$4}" | sed "s/Full *\(:VolumeTag=\)*//"
>> ## grs 20150529
>>          cat ${TMPFILE} | grep " Storage Element [0-9].*:.*Full"| sed
>> "s/.*Storage Element //" | sed "s? IMPORT/EXPORT??" | sed "s/Full
>> :VolumeTag=//"
>> =======================
>> To recognise the mail slot correctly.
>>
>> Be wary of line-wrapping in the above code.
>>
>> I haven't updated for a while, newer versions of mtx-changer may not
>> need these changes.
>>
>> And the Python version may not either.
>>
>>         Cheers,
>>                 Gary    B-)
>>
>>
>> _______________________________________________
>> Bacula-users mailing list
>> Bacula-users@lists.sourceforge.net
>> https://lists.sourceforge.net/lists/listinfo/bacula-users
>>
>
_______________________________________________
Bacula-users mailing list
Bacula-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-users

Reply via email to