What do you think about MSL 2040 instead of MSL 1/8 ? Are there the same autochager capabilities ? >From Bacula point of view is the same device ? Bye Enrico
Il giorno dom 3 mar 2024 alle ore 08:12 enrico.becche...@gmail.com < enrico.becche...@gmail.com> ha scritto: > many thanks for these informations. > Best regards > Enrico > > Il giorno dom 3 mar 2024 alle ore 03:23 Gary R. Schmidt < > g...@mcleod-schmidt.id.au> ha scritto: > >> On 03/03/2024 03:50, enrico.becche...@gmail.com wrote: >> > >> > Dear all, I need to build a backup system and I would like to use >> > Bacula. My project involves an HP Store Ever MSL 1/8 library with an >> > LTO-8 fiber channel drive. The Bacula server will be an HP Proliant >> > DL380 Gen8 running Almalinux 8 or 9. My idea is to have automatic tape >> > management with Bacula sending the tape change command when needed, and >> > the library identifying the correct cartridge using the barcode. Do you >> > think Bacula can handle all of this with the hardware I have specified? >> >> Yes. I have a previous version of that autoloader running an LTO06 tape >> drive. >> >> I had to set the timeouts to 30 seconds in mtx-changer.conf, and changed >> the mtx-changer script thus: >> >> ======================= >> wait_for_drive() { >> i=0 >> while [ $i -le 300 ]; do # Wait max 300 seconds >> # grs, try once before checking... >> mt -f $1 status > /dev/null 2>&1 >> if mt -f $1 status 2>&1 | grep "${ready}" >/dev/null 2>&1; then >> break >> fi >> debug $dbglvl "Device $1 - not ready, retrying..." >> sleep 1 >> i=`expr $i + 1` >> done >> } >> ======================= >> >> And, in the "list)" command, I changed >> ======================= >> ## cat ${TMPFILE} | grep " Storage Element [0-9]*:.*Full" | awk >> "{print \$3 \$4}" | sed "s/Full *\(:VolumeTag=\)*//" >> ## grs 20150529 >> cat ${TMPFILE} | grep " Storage Element [0-9].*:.*Full"| sed >> "s/.*Storage Element //" | sed "s? IMPORT/EXPORT??" | sed "s/Full >> :VolumeTag=//" >> ======================= >> To recognise the mail slot correctly. >> >> Be wary of line-wrapping in the above code. >> >> I haven't updated for a while, newer versions of mtx-changer may not >> need these changes. >> >> And the Python version may not either. >> >> Cheers, >> Gary B-) >> >> >> _______________________________________________ >> Bacula-users mailing list >> Bacula-users@lists.sourceforge.net >> https://lists.sourceforge.net/lists/listinfo/bacula-users >> >
_______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users