Were there any errors written to the syslog during the backup?

Does the tape work with mt and dd after stopping bacula-sd?  E.g. something
like

mt -f /dev/tape/by-id/scsi-C3EB53C004-nst rewind
dd if=/dev/tape/by-id/scsi-C3EB53C004-nst count=1 | od -c

__Martin


>>>>> On Fri, 22 Mar 2024 14:35:53 +0100, MMag Dr Karl Kashofer said:
> 
> Dear all !
> 
> I try to work with a 50 slot Quantum Scalar i3 Library with an IBM LTO7 
> drive. I have a set of 10 LTO7 tapes as a
> storage pool in bacula and it has been backing up user directories for a 
> while.
> 
> Recently we needed to swap the library chassis due to drive issues. I 
> unmounted the library, shut down bacula,
> transferred the tapes to the new library (again a Quantum Scalar i3 with the 
> drives from the old one), adjusted the scsi
> paths of the storage demon config and fired up bacula. During the change I 
> did switch from the "st" to the "nst" devices
> as apparently these are preferred.
> 
> Bacula now sees the changer device, sees the pool of tapes, but when it tried 
> to do the next backup it horribly died on
> the current append volume with:
> 
> 22-Mar 08:42 bacula-sd JobId 1245: Error: [SE0203] The Volume=MU0014L7 on 
> device="LTO7-0" (/dev/tape/by-id/scsi-
> C3EB53C004-nst) appears to be unlabeled.
> 
> There is already 45GB of data on that tape and i really dont see why it 
> suddenly calls it "unlabeled".
> 
> Any idea what could be wrong ?
> 
> I did find this thread and am unsure if thats related:
> https://bacula-users.narkive.com/JWcvt8eZ/bacula-loses-tape-label
> 
> Please help,
> Thanks,
> Karl
> 
>  
> -- 
> MMag. Dr. Karl Kashofer <k...@kashofer.org>
> 
> 
> _______________________________________________
> Bacula-users mailing list
> Bacula-users@lists.sourceforge.net
> https://lists.sourceforge.net/lists/listinfo/bacula-users
> 


_______________________________________________
Bacula-users mailing list
Bacula-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-users

Reply via email to