On 2/25/25 5:05 PM, Rob Gerber wrote:
Bill, I'm adopting your baculabackupreport python script and I've found some 
strange behavior.

I have copy and pasted some variables from the script into the ini file. I didn't change many of the ones I pasted in, I more wanted to 'bookmark' them by putting them in the ini file so I could find them easily later if I decided to experiment with them.

The trouble I've encountered a couple times now is that sometimes the script doesn't like the variables as originally quoted in the script.

For example, I copied over this variable, exactly as you see it here:
alwaysfailcolumn = 'jobname'    # Column to colorize for "always failing jobs" 
(column name, row, none)

But now the previously correctly working script says this:

[bacula@td-bacula baculabackupreport]$ /opt/baculabackupreport/email_daily.sh
- Reading configuration overrides from config file '/opt/baculabackupreport/my.ini', section 'DEFAULT' (if exists), and section 'Daily'

The 'alwaysfailcolumn' name ''jobname'' not valid or not in cols2show.

It looks like the script handles the single quoted variables fine when they're in the script itself, but tries to add them when the variable is in the ini. The trouble goes away if I remove the single quote marks.

Hello Rob,

Yes, this is the normal way the Python configparser module works with these standard 
"ini" files.

Take a look at the example baculabackupreport.ini file in the repository.

Specifically, look at the `cols2show` examples with multiple entries (all completely unquoted), and then the rest of the single entry variables - they are all unquoted.


Hope this helps,
Bill

--