I used the IBM Tape Diagnostic Tool and it seems to be indeed a hardware fault of the drive.
Thank you for the help! On Thursday, March 21, 2024 at 3:39:25 PM UTC+1 Philipp Storz wrote: > Am 21.03.24 um 13:50 schrieb Mario Kneidinger: > > I get a bareos error on the backup jobs and wonder, if the drive is > broken. Has anyone an idea, > > what I could try? > > - You could try to load a cleaning tape into your drive and see if > cleaning helps > > - Use the drive vendors' diagnostic program, like HPE Library and Tape > Tools (L&TT) or IBM Tape > Diagnostic Tool (ITDT). These tools will probably tell you the details > about the error you have. > > > I get this error in Bareos: > > > > ``` bareos-sd JobId 30873: Error: stored/block.cc:1057 Read error on > fd=6 at file:blk 0:0 on > > device "tapedrive-0" (/dev/tape/by-id/scsi-35000e11162fc2001-nst). > ERR=Input/output error. ``` > > > > I tried using other tapes, but that does not work either. I tried > relabeling the tapes but this > > does not work either and I get an error. Not even manually writing to > the tapes with 'mt' works > > and I get the error > > > > ``` /dev/nst0: Input/output error mt: The tape is write-protected. ``` > > > > Drive status on the tape roboter says: Drive Error Code 3 When I start > diagnostics on the tape > > roboter it says on all tests passed and after cleaning the drive it > shows no error code, until I > > try labeling the tapes. > > > > When asking the status with 'mtx' I get "/dev/sch0 is not an sg device, > or old sg driver". > > You need to use the scsi generic (/dev/sgX) of your changer for mtx. This > will probably still not > show you > > > > > > So is there anything left that I could try? > > > > -- You received this message because you are subscribed to the Google > Groups "bareos-users" > > group. To unsubscribe from this group and stop receiving emails from it, > send an email to > > [email protected] <mailto: > [email protected]>. To > > view this discussion on the web visit > > > https://groups.google.com/d/msgid/bareos-users/374dcbd6-a39f-43fc-b8a8-368968fdef14n%40googlegroups.com > > < > https://groups.google.com/d/msgid/bareos-users/374dcbd6-a39f-43fc-b8a8-368968fdef14n%40googlegroups.com?utm_medium=email&utm_source=footer > >. > > -- > > > Mit freundlichen Grüßen > > Philipp Storz [email protected] > Bareos GmbH & Co. KG Phone: +49 221 63 06 93-92 <+49%20221%2063069392> > http://www.bareos.com > > Sitz der Gesellschaft: Köln | Amtsgericht Köln: HRA 29646 > Geschäftsführer: Stephan Dühr, Jörg Steffens, Philipp Storz > > -- You received this message because you are subscribed to the Google Groups "bareos-users" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. To view this discussion on the web visit https://groups.google.com/d/msgid/bareos-users/9fb40ca4-25cf-410d-9655-385defd666c9n%40googlegroups.com.