As stated in an old discussion, the prim_rx_nb.c file should be modified to change the time slot number: "l1s_rx_win_ctrl(arfcn, L1_RXWIN_NB, 0);” however if i change it to another number (ex: 2,4,6), the phone will not be able to detect the BCCH signal of the BTS so it will not connect to the network. Am I changing the wrong parameter ?
Best regards, Robert, On Mar 16, 2016, at 4:06 PM, Harald Welte <[email protected]> wrote: > On Wed, Mar 16, 2016 at 02:56:45PM +0200, robert wrote: >> I’m thinking about modifying some code to have the phone listen to the >> paging group corresponding to my IMSI. > > yes, that kind of modification would be a 'bug fix', and one that we'd > like to receive. > >> Do you think it is doable or are there some hardware limitations that >> could prevent this ? > > There certainly is no limitation in the hardware, if paging works with > the original Motorola/Compal firmware. > > -- > - Harald Welte <[email protected]> http://laforge.gnumonks.org/ > ============================================================================ > "Privacy in residential applications is a desirable marketing option." > (ETSI EN 300 175-7 Ch. A6)