On Jul 26, 2017, at 4:50 PM, Sylvain Munaut <[email protected]> wrote:
>> I have attached a .pcap file showing a location update and then an >> originated call. > > As suspected CCCH-CONF is 6, so it uses other timeslots than 0 for > paging and which time slots is used for your SIM depends on a formula > and the IMSI, you can't just select it. Currently osmocom-bb only > support timeslot 0, so you're out of luck there, you'll need to add > support for it yourself if you want to use it. > If I intend to use only one phone (always same IMSI) on only one specific BTS I would be able to calculate the timeslot, in this case is it possible to have the value of the timeslot hardcoded as a start for testing since I’m still new to osmocombb and must read a lot of code before being able to adjust it for my needs. Best regards,