..should be fixed, thanks.
___________________________

On Wed, Feb 6, 2013 at 1:46 PM,
<[email protected]> wrote:
> Dear Christian,
>
> thanx! That's fine for me. I wondered how expensive it might be to
> instantiate a Serializer.
>
> One problem remains: In SAXSerializer line 253 the initializiation of Attr
> is missing. This leads to NPE. Fix:
>
> private Atts decls = new Atts();
>
> If there are more problems I'll be happy to report them to you :D
>
>
> Mit freundlichen Grüßen/Best regards
> Dr. Michael Hedenus
> Software Developer
> Powertrain Engine Systems CSW ETV RGB T2
> PIXEL GmbH
> Im Gewerbepark C15, 93059 Regensburg, Germany
>
> Telefon/Phone: +49 941 790-6362
> Telefax: +49 941 79013-90771
> E-Mail: [email protected]
> www.continental-corporation.com
> ______________________________________________________________________
> Continental Automotive GmbH, Siemensstr. 12, 93055 Regensburg, Germany
> Geschäftsführer/Managing Directors: Helmut Matschi, Gérard Cordonnier,
> Harald Stuhlmann
> Sitz der Gesellschaft/Registered office: Hannover
> Registergericht/Commercial registry: Hannover, HRB 59424, USt-Id. Nr.
> DE814950663
> _______________________________________________________________________
> Proprietary and confidential. Distribution only by express authority of
> Continental AG or its
> subsidiaries.
>
> _______________________________________________
> BaseX-Talk mailing list
> [email protected]
> https://mailman.uni-konstanz.de/mailman/listinfo/basex-talk
>
_______________________________________________
BaseX-Talk mailing list
[email protected]
https://mailman.uni-konstanz.de/mailman/listinfo/basex-talk

Reply via email to