Could be. That issue we have not seen. The one we did see was addressed by
the capacitor change. I will look at this for a later revision, assuming we
can duplicate it. But it won't be in the next revision for sure.

Gerald



On Fri, Dec 20, 2013 at 10:26 AM, <[email protected]> wrote:

> Thanks Gerald.
>
> You changed C24 to a 2.2uF capacitor to improve the reset signal but we
> don't think that fix the issue.
> We made some measurements around UART0 and we are convinced that u-boot
> detects spurious data during start up. Find below 2 ocilloscope screenshots
> (CH1 :  PIN 3-J1   B_UART0_TX, CH2 :  PIN 4-J1 B_UART0_RX).
> http://hpics.li/9d7742f
> http://hpics.li/956957a
> RX signal looks noisy when TX signal changes. Maybe a coupling issue?
>
> Regards,
>
> Ludovic
>
> --
> For more options, visit http://beagleboard.org/discuss
> ---
> You received this message because you are subscribed to the Google Groups
> "BeagleBoard" group.
> To unsubscribe from this group and stop receiving emails from it, send an
> email to [email protected].
> For more options, visit https://groups.google.com/groups/opt_out.
>

-- 