Hello Fisher! A lot of questions ...
The eHRPWM modules use a 16 bit counter (max. resolution 17 bit in up-down mode). Each A output has extended time resolution capability, while the B output only has conventional PWM capabilities. The eCAP modules use a 32 bit counter. (AFAIR just one header pin is connected.) There're 3 eQEP modules. There's an 8 channel ADC in the CPU, but the last channel (AIN7) is not connected to a header pin (instead it measures the board voltage). So 12 bit / 7 channel ADC is available. Find some inspiration on using the PRUSS in my project libpruio <http://beagleboard.org/project/libpruio/>. Here's a direct link to the online-documentation <http://users.freebasic-portal.de/tjf/Projekte/libpruio/doc/html/>. Good luck for your project. -- For more options, visit http://beagleboard.org/discuss --- You received this message because you are subscribed to the Google Groups "BeagleBoard" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. For more options, visit https://groups.google.com/d/optout.