I've observed this 3 or 4 times always while I hear thunder and storms are 
in the area.  My BBW is on a UPS and none of the crashes seem to correlate 
with UPS "beeps" or room light abnormalities, although I have good 
correlation between lighting on the security camera video and the last 
hearbeat from the BBW. 

The reset button will not start it.  I have to remove the 5V power barrel 
connector wait ~20-30 seconds and re-plug, then it boots.

My RPi2, also part of my IOT project, and on the same UPS, has never 
glitched.  I plan on wiring up a DPDT relay with the power to the BBW 
delivered through NC contacts and when the RPi2 detects the BBW IOT 
"heartbeat" has stopped to energize the relay for 30 seconds to cycle the 
power.

On Thursday, August 18, 2016 at 10:29:08 AM UTC-5, Wulf Man wrote:
>
> try a different power supply. the PMIC is picky cant be too fast or too 
> slow of a ramp up.
>
>

-- 