Hello,

We have a problem with a destroyed notebook USB port when it was connected 
to BeagleBone Black.
Our system: we designed an extension board connected to the BBB pin-headers 
P8 and P9. Let's call this the 'ERTEC board'. The ERTEC board supplies 
power to BBB via the connector P9, pins 5, 6, which is VDD_5V. The VDD_5V 
rail in BBB is basically the barrel jack input. The picture below shows the 
setup:

[image: smoke_from_notebook_usb.png]
*Normally the system works fine. *

But now one colleague reported this problem:
1. He had the Mini-USB of BBB connected to a PC (which is grounded...), and 
the whole system was powered from a +24V isolated supply and running.
2. While the system was running, he pulled the USB cable from the PC and 
connected it to a USB3.0 port of a notebook.
3. The USB connector of laptop started smoking. The laptop and BBB didn’t 
work after that.

Any idea why this could happen? So far it seems like an one-off event, but 
one could never know :-/

Thanks,
Jaroslav

-- 
For more options, visit http://beagleboard.org/discuss
--- 
You received this message because you are subscribed to the Google Groups 
"BeagleBoard" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
To view this discussion on the web visit 
https://groups.google.com/d/msgid/beagleboard/90b8ff71-1cd4-4a26-adce-70c8806f5c4f%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.