Hi,
The limit is in the RAM on the WiLink8. There is only enough to hold the 
state information for 10 connections.
The 11th connection will just fail.
Iain

On Friday, April 5, 2019 at 3:25:46 PM UTC+1, don_wrt wrote:
>
> Dear All,
>
> At most how many beaglebone black wireless modules have you ever connected 
> to each other at the same time within a mesh network ? There are some 
> constraints for TI Wilink8 chip. One of them is maximum number of connected 
> peers per single peer in the network. It is 10 in the user guide doc. Is it 
> a Wilink8 hardware caused limit or driver limit? What will be possible 
> results when connecting more than 10 beaglebones at the same time within a 
> network?
>