> The serialnumber in the SOA record is lower than the serial number BIND
> pretends to load in the logs. But why would BIND log to load the right
> zone, but use an old one?

Because it's loading the wrong file? 

Have you (or somebody else) changed `directory' option or path to master
zone file?

        -JP