On 07.07.18 11:31, Blason R wrote:
Well after numerous try I could not succeed hence then I had to delete the block.now.db file and had to restart the service it then done the AXFR and later IXFR started as well.
have you incremented the serial number on master? if the serial on the slave is bigger or the same as the one on the master (or the one in the NOTIFY), slave does not try to xfer the zone. -- Matus UHLAR - fantomas, uh...@fantomas.sk ; http://www.fantomas.sk/ Warning: I wish NOT to receive e-mail advertising to this address. Varovanie: na tuto adresu chcem NEDOSTAVAT akukolvek reklamnu postu. WinError #99999: Out of error messages. _______________________________________________ Please visit https://lists.isc.org/mailman/listinfo/bind-users to unsubscribe from this list bind-users mailing list bind-users@lists.isc.org https://lists.isc.org/mailman/listinfo/bind-users