Juha is right - <workunit><name> has to match <result><wu_name>, NOT to
<result><name> - my mistake.
On Sunday, 27 November 2016, 15:38, Juha Sointusalo
<[email protected]> wrote:
On 27 November 2016 at 17:20, Jean Philippe EIMER <[email protected]> wrote:
>
> I agree, I also noticed <app_version> has the info.
> But, the <coproc> info is not in <workunit> or <result>.
>
You need to use app_name, app_version, platform and plan_class quadruplet
to identify an app version.
Workunit has app_name and app_version, result has platform, version_num and
plan_class and a reference to workunit.