Ottawa Canada Hello Dawn:
If the Juliet and Mpower are not communicating via the serial port properly, check the following settings on both the Mpower and Juliet: Data bits parity baud rate and handshaking. The settings must be set the same on both the Juliet and the Mpower for them to be able to communicate correctly. If they are different, change either the Mpower or Juliet's settings so they are the same and they should be able to talk to each other. I've dealt with a lot of serial ports in my time and matching their settings can be very frustrating even for an experienced user. Brian -- No virus found in this outgoing message. Checked by AVG Free Edition. Version: 7.1.385 / Virus Database: 268.4.1/312 - Release Date: 14/04/2006 ___ To leave the BrailleNote list, send a blank message to [EMAIL PROTECTED] To view the list archives or change your preferences, visit http://list.humanware.com/mailman/listinfo/braillenote