Hi Phil, you can just quit Support Info mode. It sounds like the mPower has decided that it's still in a battery cycle, which it does when there's a file on the Flash Disk called "Battery cycle in progess". You should find that pressing SPACE with E will automatically removes the file, and then next time you restart it won't go into support information mode.
Since the charging hardware is fairly autonomous, it will charge whether KeySoft is in the battery cycle mode or not. There's a chip inside that watches the battery voltage, state of charge, and so on, and that decides whether to charge the battery or not. The Support Information mode recalibration options basically just take it through a cycle by forcing it to discharge and then recharge, but in normal use this will happen anyway. regards, Andy. ---- Andrew Riden Software Development Engineer HumanWare Ltd. 11 Mary Muller Drive, Christchurch, New Zealand. DDI +64 3 940 2264 Fax +64 3 384 4933 Email: [EMAIL PROTECTED] Internet: www.humanware.com ___ To leave the BrailleNote list, send a blank message to [EMAIL PROTECTED] To view the list archives or change your preferences, visit http://list.humanware.com/mailman/listinfo/braillenote