At 03:32 PM 2/10/2012, you wrote:
Hi Ira - nope, Insulation is not wet - as far as I can tell, the primary leak is coming from where the bottom tube comes out of the front boiler, and the secondary leak is coming from just below the nut that screws into the back boiler
If it's pipe threads, Loctite 565 or 567 is the proper stuff, if it's a gasket, it gets harder, as you need it the right thickness so it aims the right way just when it gets tight. I have a couple sticks of Teflon rod and a small lathe I use when I have that problem.
Teflon tape might work depending on what it looks like when you get it apart, just make sure you start wrapping 1 thread back so none gets in the boiler
Ira
-- You received this message because you are subscribed to the Google Groups "Brewtus" group. To post to this group, send email to [email protected]. To unsubscribe from this group, send email to [email protected]. For more options, visit this group at http://groups.google.com/group/brewtus?hl=en.