Looking for some help if possible. Installed the PID in the Fall. Heating element went. Sent back to WLL and they fixed that, among other things. I had the machine working for around a week and the safety valve blew. Long story short, I purchased a new pstat and safety valve. Installed them tonight and no matter where I set the pstat, the pressure in the steam boiler continues to rise until the safety valve starts to hiss. It will go we'll above 1.5. 1.7, 1.8. Any ideas what old be causing it? After initial install I removed the tube leading o the pstat to check for debris. I found none, and none in the pstat.
-- You received this message because you are subscribed to the Google Groups "Brewtus" group. To unsubscribe from this group and stop receiving emails from it, send an email to brewtus+unsubscr...@googlegroups.com. To post to this group, send email to brewtus@googlegroups.com. Visit this group at http://groups.google.com/group/brewtus?hl=en. For more options, visit https://groups.google.com/groups/opt_out.