Hello Todd,

Sunday, November 25, 2018, 7:47:49 AM, you wrote:

> I have a customer who needs to replace his AKO controller and
> does not want to upgrade due to his technical abilities.

One thing about the normal AKO is it often arrives set up for cooling, not 
heating and the customer may need to go into the settings and change it to 
heating mode. Also, it will show temperature over shoot which will seem odd 
until the customer gets use to it. Other than those two things, it's a drop in.

-- Ira

-- 