Back in business - this has to be the shortest down time i have ever had!
Thanks Todd! On Monday, September 2, 2019 at 2:24:44 PM UTC-4, todds wrote: > > The top connection the 110 volt power going to the pressure stat. > The middle one is the NO and has the wire that goes to the brew boiler > static relay. > The bottom one is the NC and that leads to the Steam boiler. > > > On Mon, Sep 2, 2019 at 2:16 PM StevieG. <[email protected] <javascript:>> > wrote: > >> Hi All, >> >> My old Jaeger pressure stat finally failed, and I have a new one that I >> bought a while ago from WLL. The new one doesn't have any labels on the >> connections, and I don't have a diagram. >> >> Anybody know where the power, NO, and NC connections go on the new unit, >> and what the dial is for? >> >> Pic attached, thanks for any assistance! >> >> Steve >> >> -- >> You received this message because you are subscribed to the Google Groups >> "Brewtus" group. >> To unsubscribe from this group and stop receiving emails from it, send an >> email to [email protected] <javascript:>. >> To view this discussion on the web visit >> https://groups.google.com/d/msgid/brewtus/1b3756ee-cfa8-4fd8-977e-cf6d02d86288%40googlegroups.com >> >> <https://groups.google.com/d/msgid/brewtus/1b3756ee-cfa8-4fd8-977e-cf6d02d86288%40googlegroups.com?utm_medium=email&utm_source=footer> >> . >> > -- You received this message because you are subscribed to the Google Groups "Brewtus" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. To view this discussion on the web visit https://groups.google.com/d/msgid/brewtus/6be12721-ec89-4ef5-8d79-c642a590d4ee%40googlegroups.com.