On Thu, Nov 05, 2015 at 11:23:44AM -0500, Ioana Danes wrote:
> I had log_min_duration_statement set at 2 seconds and the time for the
> statement was logged at something over 200  seconds

Great, thanks for that confirmation. When I get some tuits I will 
see if I can duplicate this locally and see what can be done.

> I checked the code and I think I found the scenario where records could be
> missed to be replicated.It is caused by the assumption that txntime is
> unique or all the records with the same txntime are processed during the
> same sync.

Yes, that is one of our core assumptions! It would definitely be responsible 
for the issue you are seeing. I will think about some solutions to that....

-- 
Greg Sabino Mullane [email protected]
End Point Corporation
PGP Key: 0x14964AC8

Attachment: signature.asc
Description: PGP signature

_______________________________________________
Bucardo-general mailing list
[email protected]
https://mail.endcrypt.com/mailman/listinfo/bucardo-general