On Thu, Nov 05, 2015 at 11:23:44AM -0500, Ioana Danes wrote: > I had log_min_duration_statement set at 2 seconds and the time for the > statement was logged at something over 200 seconds
Great, thanks for that confirmation. When I get some tuits I will see if I can duplicate this locally and see what can be done. > I checked the code and I think I found the scenario where records could be > missed to be replicated.It is caused by the assumption that txntime is > unique or all the records with the same txntime are processed during the > same sync. Yes, that is one of our core assumptions! It would definitely be responsible for the issue you are seeing. I will think about some solutions to that.... -- Greg Sabino Mullane [email protected] End Point Corporation PGP Key: 0x14964AC8
signature.asc
Description: PGP signature
_______________________________________________ Bucardo-general mailing list [email protected] https://mail.endcrypt.com/mailman/listinfo/bucardo-general