Hello Pierce,

Try to connect port of P-transistor and Metal1-P
Active contact by
a short P-Active arc.

If nodes are not connected by arc, Electric doesn't
know that you want them to be connected,
and it thinks that you overlapped them accidently.

  -Dima
Hello,
   
  Is there a way to stop designated DRC errors? For example, when a Metal1-P 
Active connector is placed on a P transistor active region, a DRC error is 
generated:
   
  DRC error 4 of 7: Spacing (layer P-Active): node Metal-1-P-Active-Con 
OVERLAPS arc P-Active [rule 2.2]
   
  However I am merely connecting the transistor drain, so I would like to 
suppress this error. 
   
  Other times like layers might be intended to touch and a DRC error is 
correctly generated. However, I would often like to selectively suppress these 
errors as well. Is there a way to do this? 
   
  Thanks very much,
  Pierce

       
---------------------------------