I highly appreciate that you have coded this nice tool,
as it allows me to show customers some diagrams without
requesting them to dive through endless listings.
I could manage to convert a standard vcd file from verilog or modelsim
to be read into electric, but I could not manage to view the states Z or z
and maybe resistive 1 or resistive 0.
Just a sample dump file holding the slang used to do this would be fine.
The Electric VCD reader for Verilog output handles just 4 states: 0,
1, X, and Z. It does not handle "resistive 1" or "resistive 0". I
am unfamiliar with VCD file syntax for those states. If you have a
SMALL example file, please send it to me.
-Steven Rubin
_______________________________________________
Bug-gnu-electric mailing list
[email protected]
http://lists.gnu.org/mailman/listinfo/bug-gnu-electric