David Bobroff <[email protected]> writes:

> I got a surprise when a cancelling accidental was printed at the
> beginning of a measure.  This happened following a cadenza.  Short
> example below:
>
>
> %%%
> \version "2.14.2"
>
> \relative c'
> {
>   \key c \major
>   \cadenzaOn
>   fis4 g a b
>   \cadenzaOff
>   \bar "|"
>   f
> }
> %%%
>
> Is this a bug?

Don't think so.  \cadenzaOn switches off all timing (which is the whole
idea behind it).  Your whole example does not leave bar 1.  The manual
bar line does not change that.  You can probably write something like
<< { \cadenzaOn fis4 g a b \cadenzaOff } \\ s1 >> if you want timing to
continue.

Incidentally: your example does not look like a cadenza at all.

-- 
David Kastrup