2018-05-22 9:04 GMT+02:00 Arkhipenko Alexey <rual...@gmail.com>: > % SORRY FOR LONG BUG REPORT! I COULDN'T MAKE IT SHORTER > % While score is taking 2 lanes, adding volta to measure 6 makes breath > sign in measure 6 move one note forward > % Screenshot of result: https://i.imgur.com/aqL5GS9.png > % Can be "fixed" by removing first voice or by removing volta > > \version "2.18.2" > \language "english" > > << > \new Staff { > \clef "treble" \key d \minor > { > d'1 e'1 f'1 g'1 > \glissando > c''1 bf'1 c'' d'' e'' > } > } > \new Staff { > \clef "bass" \key d \minor > { > r4 d4 e4 f4 g4 a4 > \breathe > f4 g4 a4 c'4 d'4 c'4 bf4 d4 g4 f4 e4 c4 bf,4 > \breathe > a,4 g,4 a,4 g,4 > \breathe > \set Score.repeatCommands = #'((volta "1")) > f,4 e,4 g,4 a,4 b,4 cs4 > \set Score.repeatCommands = #'((volta #f)) > e4 f4 e4 d1 > > } > } >>> > > Best regards, > Alexey Arkhipenko. > http://arkhipenko.weebly.com
Hi, I think the wrongly positioned BreathingSign is only a symptom of the underlying bug. It's the VoltaBracket being off. Below I made some code to highlight it more clearly. \relative c << \new Staff \repeat unfold 3 c'1 \new Staff { \repeat volta 1 { \autoBeamOff R1 \break f2. } \alternative { { \repeat unfold 4 b16 \repeat unfold 8 b16 } } \repeat unfold 8 f16 } >> I tested it from 2.21.0 downwards. 2.12.3 was the last stable version without this bug, see attached. Cheers, Harm
_______________________________________________ bug-lilypond mailing list bug-lilypond@gnu.org https://lists.gnu.org/mailman/listinfo/bug-lilypond