My primary domain paniced due to FFS/softdep while;  after rebooting it
i noticed one out of six guest domains having paniced as well.

This paricular one is the only one having a PCI-E device passed through,
namely one of the RAID controllers, see mpii0 in dmeg below.

mpii0 exports four identical devices with 200G each,  I am using those
as RAID0 chunks.

Complete `ldomctl console' log from DDB to reboot follow;  the guest is
running a snapshot from april, 20th.


ddb{5}> bt
data_access_fault(40079db6360, 30, 1137b6c, 0, 0, 1) at data_access_fault+0x2f0

sun4v_datatrap(4000cd1f780, 4000cd1f780, 4000cd1fa80, ec00, 200, 5) at 
sun4v_datatrap+0x210
mpii_start(4000cd1ac00, 4000cd32490, 4000cd32490, 4, 0, 40079d58c40) at 
mpii_start+0x5c
mpii_scsi_cmd(40079d58c00, 4000cde2e68, fffffffffffffff8, 0, 4000cd03800, 6) at 
mpii_scsi_cmd+0x214
scsi_xs_exec(4000cd03800, 0, 3590, 0, 0, 3590) at scsi_xs_exec+0x30
sdstart(0, 4000cd32490, 1, ce8f, 5d000000, 6) at sdstart+0x180
scsi_xsh_ioh(4000cde2fb0, 4000cd32490, 3380, 2000, 400368f8000, 1001) at 
scsi_xsh_ioh+0x20
scsi_iopool_run(4000cd1ae48, 4000cde5bd0, 40079db7068, 194f4d0, 0, 3) at 
scsi_iopool_run+0x58
scsi_xsh_runqueue(4000cde5b00, 4000cde2f18, fffffffffffffff8, 0, 4000cd02cc0, 
6) at scsi_xsh_runqueue+0x14c
scsi_xsh_add(1, 4000cedb890, ce80, 0, 0, 734) at scsi_xsh_add+0x74
sdstrategy(4000cde2e00, 4000ce62d00, 1, 0, 0, 6) at sdstrategy+0x110
spec_strategy(0, 5, 2000, 11, ffffffffffffffff, 3b9ac800) at spec_strategy+0x64

VOP_STRATEGY(1417180, 0, 17c3ba8, 40, 1ccb000, 194f4d0) at VOP_STRATEGY+0x4c
sr_raid_startwu(4000ce62d00, 1, 18e73b8, ce8f, 5d000000, 0) at 
sr_raid_startwu+0x88
sr_schedule_wu(0, 4000cedb890, 3380, 2000, 400368f8000, 1001) at 
sr_schedule_wu+0xa0  

ddb{5}> boot reboot
rebooting

NOTICE: Entering OpenBoot.
NOTICE: Fetching Guest MD from HV.
NOTICE: Starting additional cpus.
NOTICE: Initializing LDC services.
NOTICE: Probing PCI devices.
NOTICE: Finished PCI probing.

SPARC T4-2, No Keyboard
Copyright (c) 1998, 2018, Oracle and/or its affiliates. All rights reserved.
OpenBoot 4.38.16, 8.0000 GB memory available, Serial #83390594.
Ethernet address 0:14:4f:f8:70:82, Host ID: 84f87082.



Boot device: os  File and args: 
OpenBSD IEEE 1275 Bootblock 2.0
..>> OpenBSD BOOT 1.17

ERROR: /iscsi-hba: No iscsi-network-bootpath property
Trying bsd...
Booting /virtual-devices@100/channel-devices@200/disk@0/bsd
9748992@0x1000000+7680@0x194c200+196232@0x1c00000+3998072@0x1c2fe88 
symbols @ 0xfed64400 165+628248+431311 start=0x1000000
[ using 1060752 bytes of bsd ELF symbol table ]
console is /virtual-devices@100/console@1
Copyright (c) 1982, 1986, 1989, 1991, 1993
        The Regents of the University of California.  All rights reserved.
Copyright (c) 1995-2020 OpenBSD. All rights reserved.  https://www.OpenBSD.org

OpenBSD 6.7-beta (GENERIC.MP) #289: Mon Apr 20 19:01:53 MDT 2020
    [email protected]:/usr/src/sys/arch/sparc64/compile/GENERIC.MP
real mem = 8589934592 (8192MB)
avail mem = 8412766208 (8023MB)
mpath0 at root
scsibus0 at mpath0: 256 targets
mainbus0 at root: SPARC T4-2
cpu0 at mainbus0: SPARC-T4 (rev 0.0) @ 2847.862 MHz
cpu1 at mainbus0: SPARC-T4 (rev 0.0) @ 2847.862 MHz
cpu2 at mainbus0: SPARC-T4 (rev 0.0) @ 2847.862 MHz
cpu3 at mainbus0: SPARC-T4 (rev 0.0) @ 2847.862 MHz
cpu4 at mainbus0: SPARC-T4 (rev 0.0) @ 2847.862 MHz
cpu5 at mainbus0: SPARC-T4 (rev 0.0) @ 2847.862 MHz
cpu6 at mainbus0: SPARC-T4 (rev 0.0) @ 2847.862 MHz
cpu7 at mainbus0: SPARC-T4 (rev 0.0) @ 2847.862 MHz
"reboot-memory" at mainbus0 not configured
vbus0 at mainbus0
"flashprom" at vbus0 not configured
vrng0 at vbus0
cbus0 at vbus0
vdsk0 at cbus0 chan 0x2: ivec 0x4, 0x5
scsibus1 at vdsk0: 2 targets
sd0 at scsibus1 targ 0 lun 0: <SUN, Virtual Disk, 1.1>
sd0: 20480MB, 512 bytes/sector, 41943040 sectors
vdsk1 at cbus0 chan 0x3: ivec 0x6, 0x7
scsibus2 at vdsk1: 2 targets
sd1 at scsibus2 targ 0 lun 0: <SUN, Virtual Disk, 1.1>
sd1: 3MB, 512 bytes/sector, 6400 sectors
vnet0 at cbus0 chan 0x4: ivec 0x8, 0x9, address 00:14:4f:fb:1f:a3
vnet1 at cbus0 chan 0x5: ivec 0xa, 0xb, address 00:14:4f:f9:3c:2d
vcons0 at vbus0: ivec 0x8011, console
vrtc0 at vbus0
vpci0 at mainbus0: bus 0 to 255, dvma map 80000000-ffffffff
pci0 at vpci0
ppb0 at pci0 dev 1 function 0 "Sun SDIO PCIE" rev 0x01
pci1 at ppb0 bus 1
ppb1 at pci1 dev 0 function 0 "Sun SDIO PCIE" rev 0x01
pci2 at ppb1 bus 2
ppb2 at pci2 dev 0 function 0 "Sun SDIO PCIE" rev 0x01
pci3 at ppb2 bus 3
mpii0 at pci3 dev 0 function 0 "Symbios Logic SSS6200" rev 0x03
[EOT]

Reply via email to