on Friday 01 January 2021 at 18:56, Marcus Glocker wrote:
> On Wed, 30 Dec 2020 19:12:46 +0100
> Marcus Glocker <[email protected]> wrote:
> 
> > On Wed, 30 Dec 2020 16:16:06 +0000
> > Mikolaj Kucharski <[email protected]> wrote:
> > 
> > > On Tue, Dec 29, 2020 at 03:03:06PM +0100, Marcus Glocker wrote:  
> > > > On Mon, 28 Dec 2020 20:55:33 +0000
> > > > [email protected] wrote:    
> > > ...  
> > > > > >Fix:      
> > > > >       Per email threads on tech@ from above marc.info links
> > > > > below is not proper solution, but a workaround:
> > > > > 
> > > > > --8<--
> > > > > Index: dev/usb/ugen.c
> > > > > ===================================================================
> > > > > RCS file: /cvs/src/sys/dev/usb/ugen.c,v
> > > > > retrieving revision 1.109
> > > > > diff -u -p -u -r1.109 ugen.c
> > > > > --- dev/usb/ugen.c    25 Dec 2020 12:59:52 -0000
> > > > > 1.109 +++ dev/usb/ugen.c      27 Dec 2020 22:38:59 -0000
> > > > > @@ -441,6 +442,7 @@ ugen_do_close(struct ugen_softc *sc, int
> > > > >               DPRINTFN(5, ("ugenclose: endpt=%d dir=%d
> > > > > sce=%p\n", endpt, dir, sce));
> > > > >  
> > > > > +             usbd_clear_endpoint_stall(sce->pipeh);
> > > > >       /* MMM */ usbd_close_pipe(sce->pipeh);
> > > > >               sce->pipeh = NULL;
> > > > >      
> > > > > -->8--      
> > > > > 
> > > > > It makes my scanner work reliably. There is still a second
> > > > > problem metioned by me in
> > > > > https://marc.info/?t=160672895400002&r=1&w=2 but that's
> > > > > different issue.
> > > > > 
> > > > > However my question would be, any idea how to proceed from where
> > > > > I am at the moment? Any clues?
> > > > > 
> > > > > I've also CC'ed Natasha as she may be interested in this thread,
> > > > > as she was the one who started email threads from above
> > > > > marc.info URLs.    

I'm only catching up with the thread now, but thanks a lot for including
me, I am indeed interested in how this topic is evolve.

FWIW, I have been running with a CURRENT and this patch since April, on
my main computer (which I also use for remote working, so it's quite
extensively used). But because I'm a bit lazy and need this computer to
work, I don't update my CURRENT as often as I should.

I have scanned about a hundred pages, and used common USB devices
(keyboard, mouse, KVM masquerading as a hub, flash drive, PTP camera)
without any issue whatsoever (except for an sudden shutdown when the
power strip got loose from the wall socket, we clearly need a patch to
handle such cases).

> > Sorry, I was not clear;  I meant to say that 'scanimage -L' isn't
> > recognizing my EPSON ET-2750 device at all.  But in the meantime I
> > could get my hands on a CANON CanoScan LiDE 400, which gets
> > recognized, and it looks like I see similar issues like you do.
> > Based on that I can do some further investigations.
> 
> It looks like with xhci(4) for some reason the bulk endpoints are
> stalling after some operations, which isn't happening with ehci(4).  I
> currently can't see why this happens only with xhci(4).  That's why
> on your second attempt you see the timeouts happening, because the bulk
> endpoints still are in a stalled state.

Did you check my summary in
https://marc.info/?l=openbsd-tech&m=158729024415324&w=2 ?

If you have not already ruled it out, it seems worth considering:
XHCI-specific packet loss detection feature, which uses alternating PID
between DATA0 and DATA1, and only works when the OS and the device agree
on the current PID for the next packet.

When they get out of sync, e.g. because the OS kept the DATA1 state
after the device reset its on state to DATA0, the OS will send a DATA1
packet which will be ignored by the device as if a previous DATA0 was
lost so that both a retransmitted. Maybe the OS retries, still with
DATA1, until a timeout occurs.

AFAIU, usbd_clear_endpoint_stall() is used for the side effect of both
resetting the OS-side state to DATA0 (which I guess is done by
usbd_clear_endpoint_toggle()) and the device-side state through the
associated request UR_CLEAR_FAEATURE/UF_ENDPOINT_HALT.

> Using usbd_clear_endpoint_stall() at the pipe closing routine simply
> resets all the endpoints, which is why on the next attempt the
> transfers are working fine again.  That's probably why this was called
> a workaround, because we should understand why the endpoints are
> getting stalled in a first line with xhci(4).

I'm not sure what exactly is going on in your setup, but on mine the
stall came from the previous use which left the device and the OS
out-of-sync. Hence USB scanner working only once, because they are in
sync when both power up and get out-of-sync after the first use.

I don't remember whether I tracked out whether OpenBSD-side state is
reset when it shouldn't (e.g. because it's not stored after closing the
device) or not reset when it should (e.g. because it's stored despite
the device resetting its own state). But if I did I have completely
forgotten the conclusion.


Hoping this helps,
Natasha