#3080: Infinite loop in SPARC rtems_invalidate_multiple_instruction_lines()
-----------------------------+-----------------------------
Reporter: Sebastian Huber | Owner: Sebastian Huber
Type: defect | Status: assigned
Priority: normal | Milestone: 4.12.0
Component: bsps | Version: 4.12
Severity: normal | Keywords:
-----------------------------+-----------------------------
A
#define CPU_INSTRUCTION_CACHE_ALIGNMENT 0
is not a good idea in case the default range functions are used.
--
Ticket URL: <http://devel.rtems.org/ticket/3080>
RTEMS Project <http://www.rtems.org/>
RTEMS Project
_______________________________________________
bugs mailing list
[email protected]
http://lists.rtems.org/mailman/listinfo/bugs