I would picture it like:

Hylafax >=[Serial/RS232]=>IAXModem>=[IAX/ulaw]=>Callweaver>=[SIP/T.38]=>Peer

And vice-versa.

Currently I only transmit FAX from/to PSTN, but I think it should work 
as long as the IAX segment is contained on the same box or at least on 
the same Ethernet bus.

If it's not working, please, provide more info about where it's breaking 
and a simple test case so people can try reproducing the problem.

Regards,
--
Paulo

Andrius Kairiukstis escreveu:
> Hello,
>
> It is so stupid question, as T.38 are SIP protocol, but...
>
> Can i transmit fax this way?
>
> SIP --- T38 ---> CW === iaxmodem ====> HylaFAX;
>
> Hylafax === iaxmodem ====> CW ---- T38 ----> SIP
>
> Currently it work well, but in G711 only, it is not good to use with
> remote locations (reliable quality only for local network);
>
> May T38Gateway do this work?
> _______________________________________________
> Callweaver-users mailing list
> [email protected]
> http://lists.callweaver.org/mailman/listinfo/callweaver-users
>   