Hi all I'm trying to integrate CW on a custom board and to use T38Gateway application. The test scenario is depicted here below ---------------------------------------- ------------------------------------------- G3 Fax -------->FXS port Custom Board CW based | --------SIP-Proxy------| Custom Board CW based FXS port | ----------G3 Fax ---------------------------------------- ------------------------------------------- The Tx CallId is 207, the Rx CallId is 308. On both Callweaver PBX T38gateway has been used to handle the call (Tx and Rx side). In the test done the fax has been sent from 207 to 308. The G3 Fax are a couple of analog modems connected to PC I have attached both a capture of the network traffic sniffed and the log taken from Callweaver My feeling is that the SIP sessions has been established correctly and the switchover happen succesfully. Anyway when the couple of CW try to exchange some T38 packet, some error occurs and the fax transmission fails. I cannot see the training sequence, but many fcs-bad packet have been transmitted by both sides. Please help me to understand better what happens and where is the problem. could be an endianess problem? my CPU is a bi endian architecture.
best regards fabio antonini Kasko Networks S.r.l. Piazza Regina Margherita 67100 L'Aquila (IT) _______________________________________________ Callweaver-users mailing list Callweaver-users@callweaver.org http://lists.callweaver.org/mailman/listinfo/callweaver-users