This can wait a week or so to be addressed, but I wondered whether others had 
noticed this behavior.

When the user loaded a STANDARD-SCENES spec (both or left), and selected 
Human.PALS_B12.LEFT_AVG_B1-12.FIDUCIAL_711-2C.clean.align.73730.coord, the PALS 
inflated, and very inflated surfaces, they loaded without complaint, and the 
fiducial displayed properly.  But when switching to the INFLATED view, it 
looked like the fiducial.  And the very inflated view looked like the inflated. 
 Yet, if you opened window 2 and 3 and loaded a different surface in each of 
the three windows, and clicked a node, ID node printed three distinct 
coordinates.  So it seemed the correct surfaces were LOADED, but not DISPLAYED 
properly.

After foci were loaded and projected on the fiducial, then all three views 
righted themselves.  Projection made the display squirrelliness go away.

I have never experienced this on Linux or Mac, though I have less experience 
using Caret on Mac.  I never use Windows, so I wondered whether it could be 
specific to that platform.  I don't recall seeing this issue mentioned on 
caret-users.