I've seen this before. If you have these kind of layer 2 issues, stop  
dynamips, delete the cache files (generated in your homefolder) and  
restart it again.


--

Rick Mur
CCIE2 #21946 (R&S, Service provider)
Sr. Support Engineer -- IPexpert, Inc.

Sent from my iPhone

On 28 okt 2009, at 19:40, Mustafa Yadav <[email protected]> wrote:

> Hi guys,
>
> I have a weird situation.I am using GN3 for a hub&spoke lab.I see  my
> pvcs in hub is flabbing between deleted and active.But there is no any
> problem in spokes.Please have a look at below output.I see under sh
> int   a lot of missed  LMI stats received.What can be a cause for this
> problem?
>
> HUB#sh frame-relay pvc
>
> PVC Statistics for interface Serial0 (Frame Relay DTE)
>
>              Active     Inactive      Deleted       Static
>  Local          2            0            0            0
>  Switched       0            0            0            0
>  Unused         0            0            0            0
>
> DLCI = 101, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE =  
> Serial0
>
>  input pkts 130           output pkts 98           in bytes 10427
>  out bytes 7731           dropped pkts 0           in pkts dropped 0
>  out pkts dropped 0                out bytes dropped 0
>  in FECN pkts 0           in BECN pkts 0           out FECN pkts 0
>  out BECN pkts 0          in DE pkts 0             out DE pkts 0
>  out bcast pkts 0         out bcast bytes 0
>  pvc create time 01:00:21, last time pvc status changed 00:07:45
>
> DLCI = 103, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE =  
> Serial0
>
>  input pkts 170           output pkts 97           in bytes 11951
>  out bytes 7645           dropped pkts 0           in pkts dropped 0
>  out pkts dropped 0                out bytes dropped 0
>  in FECN pkts 0           in BECN pkts 0           out FECN pkts 0
>  out BECN pkts 0          in DE pkts 0             out DE pkts 0
>  out bcast pkts 0         out bcast bytes 0
>  pvc create time 01:00:30, last time pvc status changed 00:07:53
> HUB#
> HUB#
>
>
>
> HUB# sh run int s0
> Building configuration...
>
> Current configuration : 234 bytes
> !
> interface Serial0
> ip address 172.16.1.1 255.255.255.0
> encapsulation frame-relay
> frame-relay map ip 172.16.1.3 103 broadcast
> frame-relay map ip 172.16.1.2 101 broadcast
> no frame-relay inverse-arp
> frame-relay lmi-type ansi
> end
>
> HUB#sh int serial 0
> Serial0 is up, line protocol is up
>  Hardware is PowerQUICC Serial
>  Internet address is 172.16.1.1/24
>  MTU 1500 bytes, BW 1544 Kbit, DLY 20000 usec,
>     reliability 255/255, txload 1/255, rxload 1/255
>  Encapsulation FRAME-RELAY, loopback not set
>  Keepalive set (10 sec)
>  LMI enq sent  342, LMI stat recvd 218, LMI upd recvd 0, DTE LMI up
>  LMI enq recvd 0, LMI stat sent  0, LMI upd sent  0
>  LMI DLCI 0  LMI type is ANSI Annex D  frame relay DTE
>  FR SVC disabled, LAPF state down
>  Broadcast queue 0/64, broadcasts sent/dropped 0/0, interface  
> broadcasts 0
>  Last input 00:00:07, output 00:00:07, output hang never
>  Last clearing of "show interface" counters 00:57:55
>  Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 0
>  Queueing strategy: weighted fair
>  Output queue: 0/1000/64/0 (size/max total/threshold/drops)
>     Conversations  0/6/256 (active/max active/max total)
>     Reserved Conversations 0/0 (allocated/max allocated)
>     Available Bandwidth 1158 kilobits/sec
>  5 minute input rate 0 bits/sec, 0 packets/sec
>  5 minute output rate 0 bits/sec, 0 packets/sec
>     1705 packets input, 114806 bytes, 0 no buffer
>
>
>
>
>
>
>
>
> SPOKE2#  sh run int s0
> Building configuration...
>
> Current configuration : 234 bytes
> !
> interface Serial0
> ip address 172.16.1.3 255.255.255.0
> encapsulation frame-relay
> frame-relay map ip 172.16.1.1 301 broadcast
> frame-relay map ip 172.16.1.2 301 broadcast
> no frame-relay inverse-arp
> frame-relay lmi-type ansi
> end
>
> SPOKE2#sh int ser
> SPOKE2#sh int serial 0
> Serial0 is up, line protocol is up
>  Hardware is PowerQUICC Serial
>  Internet address is 172.16.1.3/24
>  MTU 1500 bytes, BW 1544 Kbit, DLY 20000 usec,
>     reliability 255/255, txload 1/255, rxload 1/255
>  Encapsulation FRAME-RELAY, loopback not set
>  Keepalive set (10 sec)
>  LMI enq sent  351, LMI stat recvd 352, LMI upd recvd 0, DTE LMI up
>  LMI enq recvd 0, LMI stat sent  0, LMI upd sent  0
>  LMI DLCI 0  LMI type is ANSI Annex D  frame relay DTE
>  FR SVC disabled, LAPF state down
>  Broadcast queue 0/64, broadcasts sent/dropped 12/0, interface  
> broadcasts 6
>  Last input 00:00:05, output 00:00:05, output hang never
>  Last clearing of "show interface" counters 00:58:37
>  Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 0
>  Queueing strategy: weighted fair
>  Output queue: 0/1000/64/0 (size/max total/threshold/drops)
>     Conversations  0/1/256 (active/max active/max total)
>     Reserved Conversations 0/0 (allocated/max allocated)
>     Available Bandwidth 1158 kilobits/sec
>  5 minute input rate 0 bits/sec, 0 packets/sec
>  5 minute output rate 0 bits/sec, 0 packets/sec
>     605 packets input, 24025 bytes, 0 no buffer
> --More--
> _______________________________________________
> For more information regarding industry leading CCIE Lab training,  
> please visit www.ipexpert.com
_______________________________________________
For more information regarding industry leading CCIE Lab training, please visit 
www.ipexpert.com

Reply via email to