Is this from one of our labs? Check access-lists on the switch.
-- Marko Milivojevic - CCIE #18427 Senior Technical Instructor - IPexpert YES! We include 400 hours of REAL rack time with our Blended Learning Solution! Mailto: [email protected] Telephone: +1.810.326.1444 Fax: +1.810.454.0130 Web: http://www.ipexpert.com/ On Thu, Mar 25, 2010 at 23:04, Bodnar, Edward <[email protected]> wrote: > I have 2 routers connected via Ethernet interfaces. RT1 Fa0/0 – RT2 Fa0/0 > On RT2 I have fa0/1.53 encap dot connected to a switch. That switch sees > the trunk up > > > > R1 can ping the Ip address I have on the sub interface but it cannot ping > any of the hosts on that subnet. R2 can ping any of the hosts on that > network. > > > > So R1 FA0/0 170.159.242.33/30 ------ R2 FA0/0 170.159.242.34/30 R2 > Fa0/1.53 ip address 170.159.53.1/24 hosts on network 2- 255 > > > > > > R1 can ping 170.159.53.1 but not 170.159.53.126 > > R2 can ping 170.159.53.1 and 170.159.53.126 > > > > Any thoughts? > > _______________________________________________ > For more information regarding industry leading CCIE Lab training, please > visit www.ipexpert.com > > _______________________________________________ For more information regarding industry leading CCIE Lab training, please visit www.ipexpert.com