On Sun, Mar 28, 2010 at 06:54, Patrice Ngassam <[email protected]> wrote: > Hi, > I have a customer that is dual homed to the same partner using BGP. One link > is primary and the second is backup. We are looking for scenario where the > bgp peer on the primary link will be shutdown automatically in case of > failure of the primary circuit. Traffic will failover to the backup circuit > and would never switch automatically the primary even if the circuit comes > back unless we manually re-enable the bgp peer on the primary circuit. Is > that do-able? Does anyone have a better alternative?
Take a look at "neighbor fall-over" command. You can use it to accomplish exactly what you have in mind. -- Marko Milivojevic - CCIE #18427 Senior Technical Instructor - IPexpert YES! We include 400 hours of REAL rack time with our Blended Learning Solution! Mailto: [email protected] Telephone: +1.810.326.1444 Fax: +1.810.454.0130 Web: http://www.ipexpert.com/ _______________________________________________ For more information regarding industry leading CCIE Lab training, please visit www.ipexpert.com