If not specifically asked on the exam I would set it to "Summarize". I used
to do a lot of custom signatures and saw that IPS may create a flood of
events to the management application (MARS and the like) when it is set to
"Fire All". The alert will be created by every single packet. 

 

Eugene

 

 

From: [email protected]
[mailto:[email protected]] On Behalf Of Vybhav
Ramachandran
Sent: Monday, November 22, 2010 11:04 PM
To: OSL Security
Subject: [OSL | CCIE_Security] IPS default event action

 

Hello All,

 

The default Summary mode in many signals is "Summarize". If not specifically
asked, what you would set this field to, when configuring a signal.

 

I usually set it to "Fire All".

 

Cheers,
TacACK

_______________________________________________
For more information regarding industry leading CCIE Lab training, please visit 
www.ipexpert.com